Line powered, no batteries to worry about, the CJA push to talk ADA telephone protects against dust, water and corrosion from damaging the unit. Easy to program simply.
![]() |
![]() |
![]() |
- Voltage: Phone Line Powered
- Fastening Method: Mounting Ears/Feet
- Features: Adjustable Microphone and Speaker Volume
- NEMA 4/12/4X Stainless Enclosure
- Size: Click Below For Dimensional Drawing
-
Dial number of telephone line that emergency phone is connected to.
(PHONE MUST BE ON A DEDICATED PHONE LINE)
-
Emergency phone will answer (GO ONLINE) automatically after one (1) ring.
-
When phone comes online, wait five (5) seconds before entering SECURITY CODE 1, 2, 3, 4, 5, 6.
After which you should hear two (2) beeps.
-
Enter PRIMARY NUMBER followed by #, 0, 0.
After which you should hear two (2) beeps.
-
Enter SECONDARY NUMBER followed by #, 0, 1.
After which you should hear two (2) beeps. (OPTIONAL ENTRY)
-
Enter *, 4. To start VOICE MESSAGE recording. You have sixteen (16) seconds to record message. Enter any touch tone to stop recording. (OPTIONAL ENTRY)
Must include in message “hit star to talk to caller” so the receiving party can have 2-way communication.
-
Enter IDENTIFICATION NUMBER followed by #, 2, 0. After which you should hear two (2) beeps. (OPTIONAL ENTRY)
-
HANG UP, your phone is now programmed.
DEFINITIONS
PRIMARY NUMBER is the first number the emergency phone dials.
SECONDARY NUMBER is the backup number if the first is busy.
VOICE MESSAGE is the message played to the receiver.
IDENTIFICATION NUMBER identifies the location and appears on caller ID.
SECURITY CODE is the access code (factory default: 1,2,3,4,5,6).