The DLE 200 Ring Down Circuit allows you to connect two handset type or push to talk phones to create a two way intercom system. Any CJA intercom system uses one of these to allow the two stations to connect to each other.
- Power: 120V AC / 13.8V AC, 1.25A – UL listed adapter provided
- Power Supply Current Draw: 600mA maximum
- Dimensions: 4.75” x 2.75” x 1.38” (120 mm x 70 mm x 35 mm)
- Environmental: 32°F to 90°F (0°C to 32°C) with 5% to 95% non-condensing humidity
- Ringer Output: 2.0 REN load maximum
- Talk Battery: 32V DC
- Dial Tone Level: -20 dBm with 600 ohm load
- Loop Length: 2.6 miles (4.2 km) maximum – 24 AWG twisted pair
- Maximum Data Speed: 28,800 bps
- CPC Break Time: 2 seconds or 150 milliseconds (selectable)
- Connections: (2) RJ11 jacks