SC Slack Cable Safety Switch for Winding Drum Elevators - 56103 or 56103-HS
SC Slack Cable Safety Switch for Winding Drum Elevators - 56103 or 56103-HS
Lead Time: Built Per Order 6-8 Weeks - Depending On Quantity.
Models Available / Specifications
ITEM: 56103
Standard Heavy Duty CJA Listed - Elevator Electric Contacts - 250VAC (10A) DC (1A)
Model Not Available
ITEM: 56103-HS
Hazardous Location Model - Class 1, Division 2 - Groups, A,B,C,D - Hermetically Sealed Contact Block Rated UL, CSA. Switch built to NEC Code requirements for Class 1, Division 2, Groups A,B,C & D Locations - (360VAC Inductive)
Additional Items You May Need
This Switch is used for for Winding Drum Elevators and Hoists. This Switch is designed to detect Slack or Broken Cable. You must insert a 1/2” rod into each end of the device long enough to span the area of the cable drum.
When slack on the cable or some other action pushes either lever down the heavy duty electrical contact opens requiring that it be manually reset before the elevator can move again. This is wired in to the safety circuit to shut the elevator motor down in the event the elevator car stops and the cable that winds around the drum spools off of it.
All Cast Parts
Manual Reset Lever
Downloads
56103-SC General Installation Guide
Replacement Parts
There are no replacement parts available for this switch. You must order the entire switch as a complete assembly due to how this switch is manufactured and gauged for operation.